Y203-EN2-02+Motion&Drives+Catalogue
CIMR-J7AZ
Varispeed J7
Small, simple and smart
V/f controlled inverter
Compact size
Good torque performance: 100% torque at 1.5 Hz,
150% at 3 Hz
150% overload / 60sec
Overload detection function.
Motor thermal function
Freely configurable V/f curve
4 programmable digital input
1 programmable digital output
1 programmable analog output
Optional RS-232C/485 communication - Modbus
PC Configuration tool: CX-drive
CE, UL, and cUL marking
Ratings
200 V class single-phase 0.1 to 1.5 kW
200 V class three-phase 0.1 to 4.0 kW
400 V class three-phase 0.2 to 4.0 kW
System configuration
SI-485/J7
SI-232/J7
SI-232/J7C
CX-Drive
JVOP-144
Remote digital oper.
with potentiometer
JVOP-146
Remote digital oper.
with potentiometer
3G3IV-PEZZ8122_
DIN attachment
Line filter
3G3IV-PCN329-E
Inverter to PC cable
3G3IV-PCN126/326
Digital operator
extension cable
Varispeed
J7
Varispeed J7
351
760666381.019.png 760666381.020.png 760666381.021.png 760666381.022.png 760666381.001.png 760666381.002.png 760666381.003.png 760666381.004.png 760666381.005.png 760666381.006.png
Specifications
Type designation
CIMR—J7AZ20P1
Inverter
Max. applicable motor output
0P1: 0.1 kW
J7 series
4P0: 4.0 kW
[ ]
A: With digital operator (with potentiometer)
"P" indicates a decimal
point
Z: European standard
specifications
Voltage
B: Single-phase 200 VAC
2: Three-phase 200 VAC
4: Three-phase 400 VAC
Voltage class
200 V single/three-phase
400 V three-phase
Model CIMR-J7AZ #
Three-phase
20P1 20P2 20P4 20P7 21P5 22P2 24P0 40P2 40P4 40P7 41P5 42P2 43P0 44P0
Single-phase 1
B0P1 B0P2 B0P4 B0P7 B1P5
Max. applicable
motor output kW (HP) 2
0.12 0.25 0.55
1.1
1.5
2.2
4.0
0.37
0.55
1.1
1.5
2.2
3.0
4.0
Inverter capacity kVA
0.3
0.6
1.1
1.9
3.0
4.2
6.7
0.9
1.4
2.6
3.7
4.2
5.5
7.0
Rated output current A
0.8
1.6
3
5
8
11
17.5
1.2
1.8
3.4
4.8
5.5
7.2
9.2
Max. output voltage V
3-phase, 200 to 230 V (proportional to input voltage)
Single-phase, 200 to 240 V (proportional to input voltage)
3-phase, 380 to 460 V (proportional to input voltage)
Max. output frequency
400 Hz (programmable)
Rated input voltage
and frequency
3-phase, 200 to 230 V, 50/60 Hz
Single-phase, 200 to 240 V, 50/60 Hz
3-phase, 380 to 460 V, 50/60 Hz
Allowable voltage
function
–15 to +10%
Allowable frequency
function
±5%
1. Single-phase series inverter output is three-phase (for three-phase motors)
2. Based on a standard 4-pole motor for max. applicable motor output. Select the inverter model whose rated current is larger than motor rated current.
352
Frequency inverters
760666381.007.png 760666381.008.png 760666381.009.png
Commom specifications
Model
CIMR-J7AZ #
Specifications
Control method
Sine wave PWM (V/f control)
Output frequency range
0.1 to 400 Hz
Frequency tolerance
Digital reference: ±0.01% (–10 to +50 °C),
Analog reference: ±0.5% (25±10 °C)
Resolution of frequency set value
Digital reference: 0.01 Hz (less than 100 Hz), 0.1 Hz (100 Hz or more)
Analog reference: 1/1000 of max. output frequency
Resolution of output frequency
0.01 Hz
Overload capability
150% rated output current for one minute
Frequency set value
0 to 10 VDC (20 k Ω ), 4 to 20 mA (250 Ω ), 0 to 20 mA (250 Ω ), frequency setting volume (selectable)
Accel/decel time
0.1 to 999 sex. (accel/decel time are independently programmed)
Braking torque
Short-term average deceleration torque 1 : 0.1, 0.2 kW (0.13 HP, 0,25 HP): 150% or more;
0.4/0.75 kW (0,5 HP, 1HP): 100% or more;
1.5 kW (2 HP): 50% or more;
2.2 kW (3 HP) or more: 20% or more
Continuous regenerative torque: Approx 20%
V/f characteristics
Possible to program any V/f pattern
Digital inputs
Four of the following input signals are selectable: forward/reverse run (3-wire sequence), fault reset, external fault (NO/NC
contact input), multi-step speed operation, jog command, accel/decel time select, external baseblock (NO/NC contact input),
speed search command, UP/DOWN command, accel/decel hold command, LOCAL/REMOTE selection, communication/
control circuit terminal selection, emergency stop fault, emergency stop alarm, self test
Digital outputs
Following output signals are selectable (NO/NC contact output): Fault, running, zero speed, speed agreed,
frequency detection (output frequency or set value), during overtorque detection, minor error, during baseblock,
operation mode, inverter run ready, during fault retry, during undervoltage detection, reverse running, during speed search,
data output through communication
Standard functions
Full-range automatic torque boost, slip compensation, 9-step speed operation (max.), restart after momentary power loss,
DC injection braking current at stop/start (50% of inverter rated current, 0.5 sec, or less), frequency reference bias/gain, fault
retry, speed search, frequency upper/lower limit setting, overtorque detection, frequency jump, accel/decel time switch, accel/
decel prohibited, S-curve accel/decel, frequency reference with built-in volume, constants copy (option) MEMOBUS commu-
nications (option)
Display
Status indicator LED: RUN and ALARM provided as standard LED’s
Digital operator: available to monitor frequency reference, output frequency, output current
Motor overload protection
Electronic thermal overload relay
Instantaneous overcurrent
Motor coasts to a stop at approx. 250% of inverter rated current
Overload
Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Overvoltage
Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Undervoltage
Stops when DC bus voltage is approx. 200 V or less (double for 400 V class)
(approx. 160 V or less for single-phase series)
Momentary power loss
Following items are selectable: Nnot provided (stop if power loss is 15ms or longer),
continuous operation if power loss is approx. 0.5 s or shorter, continuous operation
Cooling fin overheat
Protected by thermister
Stall prevention level
Individual level stall prevention can be set during acceleration or constant running,
provided/not provided setting available during deceleration.
Cooling fan fault
Detected by electronic circuit (fan lock detection)
Ground fault
Protected by electronic circuit (operation level is approx. 250% of rated output current)
Power charge indication
ON until the DC bus voltage becomes 50 V or less, RUN lamp stays ON or digital operator LED stays ON.
(Charge LED is provided for 400 V)
Degree of protection
IP20
Cooling
Self cooling for 200 V 0,1..0,75 kW (single-phase) 0,1..0,4 kW (Three-phase) and for 400 V 0,2..0,75l kW
Cooling fan for 200 V (single-phase), 0.75 kW..4.0 kW (3-phase) and for 400 V 1,5..4.0 kW
Ambient temperature
-10 ºC to 50 ºC (non-freezing)
Ambient humidity
90% RH or less (non-condensing)
Storage temperature
-20 ºC..+60 ºC (short-term temperature during trasnportation)
Installation
Indoor (no corrosive gas, dust, etc.)
Installation height
Max. 1000 m
Vibration
10 to 20 Hz, 9.8 m/s 2 max; 20 to 50 Hz, 2m/s 2 max
1. Shows deceleration torque for uncoupled motor decelerating from 60 Hz with the shortest possible deceleration time.
Varispeed J7
353
760666381.010.png 760666381.011.png
Digital operator
Digital operator
Data display
Function display LEDs
Selected function is lit (see the
functions below). Its data is
displayed on data display.
Display selection key
Operation key
Press to run the motor. The RUN
light is ON while running.
Switch functions among function
display LEDs.
Enter key
Enter data when setting constants.
After selecting constant no. at
PRGM mode, data are displayed.
Alarm LED
Run LED
Increment key
Increase constant no. or data.
Frequency setting volume
Set operational frequency with
volume.
Decrement key
Decrease constant no. or data.
Stop/Reset key
Press to stop the motor. If fault
occurs, reset the inverter.
FREF
FOUT
IOUT
MNTR
Frequency reference
setting/monitoring
Output frequency
monitoring
Output current
monitoring
Multi-function
monitoring
F/R
LO / RE
PRGM
Operator RUN command
FWD/REV selection
LOCAL/REMOTE
selection
Constant no./data
354
Frequency inverters
760666381.012.png 760666381.013.png 760666381.014.png 760666381.015.png
Dimensions
IP 20 type 0.1 to 4 kW
2 – M 4
4 – M 4
8.5
(0.34)
8.5
(0.34)
Figure 1
Figure 2
Voltage class
Max. applicable
motor output kW
Inverter model
CIMR-J7AZ #
Figure
Dimensions in mm
Weight kg
Cooling
method
W
H
D
W1
H1
H2
0.12
20P1
1
68
128
70
56
118
5
0.5
Self cooled
0.25
20P2
7.7
0.55
20P4
102
0.8
200 V
three-phase
1.1
20P7
122
0.9
Fan cooled
1.5
21P5
2
108
129
96
118
1.3
2.2
22P2
154
1.5
4.0
24P0
140
161
128
2.1
0.1
B0P1
1
68
128
70
56
118
5
0.5
Self cooled
0.2
B0P2
200 V
single-phase
0.4
B0P4
112
0.9
0.75
B0P7
2
108
129
96
1.5
Fan cooled
1.5
B1P5
154
0.37
40P2
2
108
128
81
96
118
5
1.0
Self cooled
0.55
40P4
99
1.1
1.1
40P7
129
1.5
400 V
three-phase
1.5
41P5
154
2.2
42P2
Fan cooled
3.0
43P0
140
161
128
2.1
4.0
44P0
Varispeed J7
355