*** Basic Information ***
========================================================================
[Create date] 2011/03/17
------------------------------------------------------------------------
[Program Name] Engine
------------------------------------------------------------------------
[Version] 1.52:03
------------------------------------------------------------------------
[PCB No.] 
------------------------------------------------------------------------
[Interchangeability] X / O
------------------------------------------------------------------------
[Other Firmware Requirements] None
------------------------------------------------------------------------
[PCB Requirements] None
------------------------------------------------------------------------
[Software category] Normal Release
------------------------------------------------------------------------
[Release category] Normal Release
------------------------------------------------------------------------
[Program category] Firmware
------------------------------------------------------------------------
Exported to(language) GEN(all)
[Firmware No.] D0395501H
[File Information]
 File Name         D0395501H.fwu
 File Type         Module for Service
 Size              3.94 MB ( 4129336 byte )
[File Information]
 File Name         D0395501H.rfu
 File Type         Module for Remote Upgrade
 Size              3.95 MB ( 4137216 byte )
------------------------------------------------------------------------
[Production reflection] 2011/02
------------------------------------------------------------------------

========================================================================
*** Note ***
========================================================================
[Note] 

------------------------------------------------------------------------


========================================================================
*** Important Notes ***
========================================================================
[Important Notes] 

------------------------------------------------------------------------


========================================================================
*** Modification History ***
========================================================================
[Modifications made:]
Symptom corrected:
Under the following conditions, the final page or the pages near the 
end of the 1st copy are stapled into the 2nd copy.
 1. The customer sets "Staple" on the printer driver and makes two
or more copies.
 2. Paper end occurs on the final page or near the end of the 1st
copy.

Other Changes:
1. When the machine is in the paper end condition during limitless
feed mode, the machine does not start the next job before the 
previous job is completed.
2. Improve the reliability of continuous action among printing jobs
while multiple continuous printing with the staple function is
selected.


------------------------------------------------------------------------
[Modification history]
----------------------------------------
Version 1.51:03
Symptom corrected:
SC552/SC555 occurs due to fusing heater damage (meltdown). 
Note: This issue only occurs on the 220V model.


----------------------------------------
Version 1.50:03
Other changes:
The amount of toner consumed by the machine in Refresh Mode was 
decreased.


----------------------------------------
Version 1.05:03
Symptoms corrected:
1. The firmware update process for a machine peripheral is 
   interrupted, and the machine does not retry the update even after 
   being rebooted.
2. The PM counter value for the AIT unit is not updated unless the 
   machine power is turned off before the unit is replaced.
3. The SP numbers for the PCU counter/rotation for Magenta and Cyan 
   are incorrect.
4. Fan motors do not stop when the waste toner bottle is full.
   Note: The related SP setting was changed to "1", so that the 
   motors shut off in one second.
Other changes:
5. The timing conditions for performing MUSIC were changed (MUSIC 
   will no longer be triggered by the elapsed time since the previous
   performance).
   Note: This is to realize the following benefits:
   - Waiting time is minimized
   - Toner consumption is reduced
   - The accuracy of the synchronization of MUSIC for the PCU and 
     development unit is increased
6. When thin paper is selected with 1200dpi mode, the fusing 
   temperature for "Plain 1" (SP1105-128 to 131) is used, which can 
   minimize paper curl.
7. (Minor change applied for the Japanese domestic model).

----------------------------------------
Version 1.04:03
1st Mass production