Komunikacja bezprzewodowa MAS21.pdf

(2644 KB) Pobierz
CS3_AB.dot
Micro Application Example
Wireless Data Communication based on GPRS
Micro Automation Set 21
14957216.014.png
Note
Micro Automation Set 21
Beitrags-ID 22537809
Note
The Micro Automation Sets are not binding and do not claim to be complete
regarding their configuration, equipment and any eventuality. The Micro
Automation Sets do not represent customer-specific solutions. They are
only intended to provide support for typical applications. You are
responsible for ensuring that the described products are correctly used.
These Micro Automation Sets do not relieve you of the responsibility of
safely and professionally using, installing, operating and servicing
equipment. When using these Micro Automation Sets, you recognize that
Siemens cannot be made liable for any damage/claims beyond the liability
clause described. We reserve the right to make changes to these Micro
Automation Sets at any time without prior notice. If there are any deviations
between the recommendations provided in these Micro Automation Sets
and other Siemens publications – e.g. Catalogs – the contents of the other
documents have priority.
Warranty, Liability and Support
We accept no liability for information contained in this document.
Any claims against us – based on whatever legal reason – resulting from
the use of the examples, information, programs, engineering and
performance data etc., described in this Micro Automation Set shall be
excluded. Such an exclusion shall not apply in the case of mandatory
liability, e.g. under the German Product Liability Act
(“Produkthaftungsgesetz”), in case of intent, gross negligence, or injury of
life, body or health, guarantee for the quality of a product, fraudulent
concealment of a deficiency or breach of a condition which goes to the root
of the contract (“wesentliche Vertragspflichten”). However, claims arising
from a breach of a condition which goes to the root of the contract shall be
limited to the foreseeable damage which is intrinsic to the contract, unless
caused by intent or gross negligence or based on mandatory liability for
injury of life, body or health. The above provisions do not imply a change in
the burden of proof to your detriment.
Copyright© 2006 Siemens A&D. It is not permissible to transfer or
copy these Micro Automation Sets or excerpts of them without first
having prior authorization from Siemens A&D in writing.
For questions about this document please use the following e-mail address:
V3.1
01.10.2007
2/65
14957216.015.png
Foreword
Micro Automation Set 21
Beitrags-ID 22537809
Foreword
Micro Automation Sets are fully functional and tested automation
configurations based on A&D standard products for simple, fast and
inexpensive implementation of automation tasks for small-scale
automation. Each of the available Micro Automatic Sets covers a frequently
occurring subtask of a typical customer problem in the low-end
performance level.
The sets help you to obtain answers with regard to required products and
the question of how they function when combined.
However, depending on the system requirements, a variety of other
components (e.g. other CPUs, power supplies, etc.) can be used to
implement the functionality on which this set is based. Please refer to the
respective SIEMENS A&D catalogs for these components.
The Micro Automation Sets are also available by clicking the following link:
V3.1
01.10.2007
3/65
14957216.016.png
Foreword
Micro Automation Set 21
Beitrags-ID 22537809
Table of Contents
Table of Contents ... ...................................................................................................... 4
1
Fields of Application and Benefits .. .............................................................. 5
2 Configuration .. ................................................................................................ 9
2.1 Layout Diagram of a Remote Station.. .............................................................. 9
2.2 Layout Diagram of the Central Station... ......................................................... 10
2.3 Hardware and Software Components... .......................................................... 11
2.4 Remote Station ... ............................................................................................ 11
2.5 Central Station ... ............................................................................................. 12
3 Function Principle .... .................................................................................... 13
3.1 SINAUT MICRO SC Server ... ......................................................................... 13
3.2 GPRS Modem SINAUT MD720-3.... ............................................................... 17
3.3 S7 Block Library... ........................................................................................... 18
3.4 Communication between Remote Stations.... ................................................. 21
3.5 Management of the send jobs ... ..................................................................... 28
3.6 Buffering of process data with real time stamp ... ............................................ 31
3.7 Archiving the process data in the Central Station ... ........................................ 33
3.8 Data Logging ... ............................................................................................... 34
3.9 Sending SMS text messages... ....................................................................... 35
3.10 Dyn-DNS Service... ......................................................................................... 36
3.11 TeleService.... ................................................................................................. 37
4 Configuring the Startup Software ... ............................................................ 38
4.1 Preliminary Remarks .... .................................................................................. 38
4.2 Downloading the Startup Code .... ................................................................... 38
4.3 Configuring Components ... ............................................................................. 38
4.3.1 SINAUT MICRO SC Server ... ......................................................................... 39
4.3.2 WinCC flexible Runtime ... ............................................................................... 39
4.3.3 Remote Station ... ............................................................................................ 40
5 Live Demo.... .................................................................................................. 44
5.1 User interface ... .............................................................................................. 45
5.3 Scenario of Remote Station “Inspection Shaft”... ............................................ 51
6 Performance Data of the Application... ....................................................... 58
6.1 Estimating the communication costs ... ........................................................... 58
6.1.1 Connection costs of the Remote Station ... ..................................................... 58
6.1.3 Connection costs of the Central Station ... ...................................................... 62
6.2
Information on connection quality .... ............................................................... 63
7
Technical data... ............................................................................................ 64
V3.1
01.10.2007
4/65
14957216.017.png
Fields of Application and Benefits
Micro Automation Set 21
Beitrags-ID 22537809
1
Fields of Application and Benefits
Automation Task
To provide good comprehensibility, the features of the Micro Automation
Set are explained using an application example.
The infrastructure of a wastewater treatment plant contains the substations
“Stormwater Overflow 1 “ and “Inspection Shaft 2 “. Both are supposed to
communicate with each other and with a control center. The Internet-based
GPRS 3 service, which charges by data volume, should be used as a data
transfer medium. The control center should enable central operator control
and monitoring.
Figure 1-1
Wastewater Treatment Plant
Stormwater Overflow:
Flow rate measurement of water influx
Measuring the filling level of the overflow structure
Overflow measurement 4
Automatic pumping of basin content to the
discharge treatment plant
Operating hours count of the pumps
Monitoring overflow structure and dry run of the
pumps
Pump
Pump
P1
P2
Stormwater Overflow
River
Wastewater
Flow
P3
Wastewater
Treatment Plant
Inspection Shaft:
Flow rate measurement of wastewater influx
Measuring the filling level of the overflow structure
•A utomatic pumping of basin content to the
discharge treatment plant
Operating hours count of the pumps
Monitoring overflow structure and dry run of the
pumps
All measuring data are to be buffered locally with
real-time stamps and non-volatilly, until they have
been sent to the Central Station successfully and
could be archived there.
• A trigger in the Central Station causes the
“Inspection Shaft“ Remote Station to send an SMS
to a telephone number specified by the Central
Station.
Inspection Shaft
Pump
1 Stormwater Overflow is a structure in the wastewater network for catching peak loads. A Stormwater Overflow
enables controlled “overflow“ (with overflow measurement).
2 Inspection Shaft is a shaft in the pipe system of the wastewater network. The Micro Automation Set
contains/simulates elements for flow measurement. This enables measuring and calculating the wastewater influx from
an industrial plant, for example.
3 GPRS : G eneral P acket Radio S ervice is a package-oriented data service in GSM networks. These are based on IP
network technology (IP = Internet protocol).
4 Overflow Measurement: Stormwater overflow structures have an overflow for surplus effluent which forms after
heavy rainfall, for example. The effluent volume is measured at an overflow edge and is referred to as overflow
measurement.
V3.1
01.10.2007
5/65
14957216.001.png 14957216.002.png 14957216.003.png 14957216.004.png 14957216.005.png 14957216.006.png 14957216.007.png 14957216.008.png 14957216.009.png 14957216.010.png 14957216.011.png 14957216.012.png 14957216.013.png
Zgłoś jeśli naruszono regulamin