LM119,219,319.PDF

(156 KB) Pobierz
HIGH SPEED DUAL BIPOLAR COMPARATORS
LM119 - LM219
LM319
HIGH SPEED DUAL COMPARATORS
. TYPICALLY 80ns RESPONSE TIME AT ± 15V
. MAXIMUM INPUT CURRENT OF 1 m A OVER
. INPUTS AND OUTPUTS CAN BE ISOLATED
FROM SYSTEM GROUND
OPERATING TEMPERATURE RANGE
. HIGH COMMON-MODE SLEW RATE
DESCRIPTION
These products are precision high speed dual
comparators designed to operate over a wide range
of supply voltages down to a single 5V logic supply
and ground and have low input currents and high
gains.
The open collector of the output stage makes
compatible with TTL as well as capable of driving
lamps and relays at currents up to 25mA.
Although designed primarily for applications
requiring operation from digital logic supplies, are
fully specified for power supplies up to ± 15V.
They feature faster response than the LM111 at the
expense of higher power dissipation. However, the
high speed, wide operating voltage range and low
package count make the much more versatile.
N
DIP14
(Plastic Package)
D
SO14
(Plastic Micropackage)
ORDER CODES
Part
Number
Temperature
Range
Package
ND
LM119
–55, +125 o C
LM219
–40, +105 o C
LM319
0, +70 o C
Example : LM219N
PIN CONNECTIONS (top view)
1
14
2
13
1 - N.C.
2 - N.C.
3 - Ground 1
4 - Non-inverting input 1
5 - Inverting input 1
6-V CC -
7 - Output 2
8 - Ground 2
9 - Non-inverting input 2
10 - Inverting input 2
11 - V CC +
12 - Output 1
13 - N.C.
14 - N.C.
3
12
4
+
11
5
-
-
10
6
+
9
7
8
April 1995
1/9
. TWO INDEPENDENT COMPARATORS
. OPERATES FROM A SINGLE +5V SUPPLY
. MINIMUM FAN-OUT OF 2 EACH SIDE
311049503.002.png
LM119 - LM219 - LM319
SCHEMATIC DIAGRAM
R1
3.5k
W
V CC
R7
R3
3k
W
4k
W
R6
3k
W
R2
Q9
4k
W
Q4
Q8
Q3
Q7
Q6
C1
18
R12
m
F
13k
W
R11
13k
W
Inverting
Input
Q2
R4
R5
R10
470k
W
3k
W
3k
W
Non-inverting
Input
Q1
R8
2k
W
Q15
Q6
R9
18k
Q10
Q13
W
R15
300
Q22
W
R23
4k
R22
60
W
R13
Output
R18
1.8k
Q14
W
W
W
600
R20
3.6k
W
Q21
Q11
Q12
Q16
Q20
R19
250
R14
2k
R16
600 W
W
W
R25
600
W
Q19
R24
250
W
R21
900
Q18
Q17
W
R17
3
W
To other half
V CC GND
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
LM119
LM219
LM319
Unit
V O -V CC -
Output to Negative Supply Voltage
36
36
36
V
V CC -
Negative Supply Voltage
25
25
25
V
V CC +
Positive Supply Voltage
18
18
18
V
V id
Differential Input Voltage
±
5
±
5
±
5
V
V i
Input Voltage – (note 1)
±
15
±
15
±
15
V
P tot
Power Dissipation
500
500
500
mW
T oper
Operating Free-air Temperature Range
–55 to +125 –40 to +105
0 to +70
o C
T stg
Storage Temperature Range
–65 to +150 –65 to +150 –65 to +150
o C
2/9
311049503.003.png
LM119 - LM219 - LM319
ELECTRICAL CHARACTERISTICS
V CC =
15V, T amb =25 o C(unless otherwise specified)
LM119 - LM219
LM319
Symbol
Parameter
Unit
Min. Typ. Max. Min. Typ.
Max.
V io
T amb = +25 o C
T min .
3
5k
W
) – (note 2)
mV
0.7
4
7
2
8
10
3
T amb
3
T max.
I io
Input Offset Current – (note 2)
T amb = +25 o C
T min .
nA
30
75
100
80
200
300
3
T amb
3
T max.
I ib
Input Bias Current – (note 2)
T amb = +25 o C
T min .
nA
150
500
1000
250
1000
1200
3
T amb
3
T max.
A vd
Large Signal Voltage Gain
10
40
8
40
V/mV
I CC +
15V
V CC + = +5V, V CC =0V
±
8
4.3
11.5
8
4.3
12.5
mA
I CC
Negative Supply Current
3
4.5
3
5
mA
V icm
Input Common Mode Voltage Range
V CC =
V
15V
V CC + = +5V, V CC =0V
±
12
1
±
13
±
12
1
13
3
3
V id
Differential Input Voltage
±
5
±
V
V OL
Low Level Output Voltage
T amb = +25 o C, I O = 25mA
V i
V
3
–5mV
0.75
1.5
V i
3
–10mV
0.75
1.5
T min.
3
T amb
3
T max.
V CC +
+4.5V, V CC = 0V, I O(sink) < 3.2mA
V i
.
3
–6mV
0.23
0.4
V i
3
–10mV
0.3
0.4
I OH
High Level Output Current (V O = +35V)
T amb = +25 o C
m
A
V i
.
5mV
0.2
2
V i
.
10mV
0.2
10
T min .
3
T amb
3
T max . i
.
5mV
1
10
t re
Response Time – (note 3)
80
80
ns
Notes : 1. For supply voltages less than
15V the absolute maximum input voltage is equal to the supply volt age.
2. These specifications apply for V CC = ± 15V, unless otherwise stated. The offset voltage, offset current and
bias current specifications apply for any supply volt age from a single +5V supply up to
±
15V supplies.
The offset voltages and offset current given are the maximum values required to drive the output down to 1V
or up to +14V with a 1mA load current.
Thus, these parameters define an error band and take into account the worst case effects of voltage gain
and input impedance.
3. The response time specified is for a 100mV input step wit h 5mV overdrive.
±
3/9
±
Input Offset Voltage (R S
Positive Supply Current
V CC =
±
±
5
311049503.004.png
LM119 - LM219 - LM319
4/9
311049503.005.png
LM119 - LM219 - LM319
5/9
311049503.001.png
Zgłoś jeśli naruszono regulamin