całościowy opis webasto alfa 166.pdf

(293 KB) Pobierz
file://F:\alfa\eLearn\Web\tempschprint.html
eLearn - Packet print
Strona 1 z 5
ADDITIONAL HEATER
166
file://F:\alfa\eLearn\Web\tempschprint.html
2010/12/01
395400254.003.png 395400254.004.png
eLearn - Packet print
Strona 2 z 5
ADDITIONAL HEATER - Description
The supplementary heater aids coolant heating immediately following start-up and during running so that the engine heats up faster and engine
service temperature and passenger compartment heating are maintained at optimal levels.
The device works completely automatically and is active only when the engine is running with outdoor temperatures less than or equal to +5  C and
coolant temperature lower than 60  C.
When coolant temperature reaches 61  C, the control unit reduces burner power and cuts off operation when the temperature reaches 72  C. It is
re-activated automatically when the fluid temperature drops to 60  C. If fluid temperature begins to drop immediately after reducing burner power,
the control unit cuts in to restore full power.
For further details see Characteristic of working principle 5020L additional heater .
The control unit supply line is protected by a fuse in the engine compartment junction unit and a relay located in the services compartment (behind
the engine bulkhead).
The relay supply line is protected by a fuse located in the junction unit.
file://F:\alfa\eLearn\Web\tempschprint.html
2010/12/01
395400254.005.png
eLearn - Packet print
Strona 3 z 5
ADDITIONAL HEATER - Functional description
Additional heater control unit M75 is supplied at pin 1 (connector B) directly from the battery. via the line protected by fuse F23 of the engine
compartment junction unit B1.
The earth is taken to pin 2 (connector B) via additional heater relay J36, switch I20 and relay T1 of junction unit B2.
When relay T1 is energised via the line (15/54) its contact supplies the coil of additional heater relay J36 via fuse F6. Control unit M75 receives an
earth signal via its contact.
Pin 3 of connector A of M75 receives a signal from the appropriate temperature sensor K79 , which measures air temperature within the engine bay.
The sensor only works with the engine running; it receives a reference signal from alternator (D+); this signal is low (earth) when the alternator is
not turning. The signal becomes high (12 V) and supplies the sensor when the engine is running. E5010 STARTING AND RECHARING
Pin 6 of connector A controls additional heater pump N44 , which is earthed through inertia switch I50 . In case of impact, this cuts off the circuit to
prevent the danger of fuel emerging.
If the intertia switch is operated it de-energizes the relay J36.
Control unit M75 is equipped with a self-diagnostic system that may be used by connecting the unit to connector R10 through pin 2 of connector A.
E8010 DIAGNOSTIC MULTIPLE CONNECTOR .
file://F:\alfa\eLearn\Web\tempschprint.html
2010/12/01
395400254.006.png
eLearn - Packet print
Strona 4 z 5
ADDITIONAL HEATER - Location of components
Component code
Name
Assembly reference
A5
Terminal board
-
A10
Alternator
-
A10
Alternator
5530A
B1
Junction unit
-
B1
Junction unit
5505A
B1
Junction unit
5505A
B2
Dashboard junction unit (CPL)
-
B2
Junction unit
-
B2
Junction unit
5505A
B5
MAXI FUSE box
-
B38
Additional heater fuse
-
B99
Battery fuses junction unit (CBA)
5530B
C10
Front left earth
-
C15
Facia earth, driver's side
-
C30
Rear left earth
-
C31
Rear right earth
-
D1
Front-dashboard coupling
-
D4
Engine front connection
-
D6
Rear - front coupling
-
D6
Rear-engine compartment coupling
-
D7
Recharging front connection
-
D19
Dashboard / battery coupling
-
D22
Additional heater junction
-
D25
Dashboard-left rear coupling
-
D25
Dashboard-rear coupling left
-
H1
Ignition switch
5520A
I50
Inertial switch
1040A
J36
Additional heater relay
5020M
J36
Webasto pump inhibitor relay.
-
K79
Air temperature sensor (additional heater)(
-
K79
Interior temperaature. sensor for additional heater
-
M75
Additional heater control unit
-
N44
Additional heater pump
-
O25
Additional heater resistance
-
R10
Multiple tester connection
-
file://F:\alfa\eLearn\Web\tempschprint.html
2010/12/01
395400254.001.png
eLearn - Packet print
Strona 5 z 5
ADDITIONAL HEATER - Wiring diagram
Component code
Name
Assembly reference
A5
Terminal board
-
A10
Alternator
-
A10
Alternator
5530A
B1
Junction unit
-
B1
Junction unit
5505A
B1
Junction unit
5505A
B2
Dashboard junction unit (CPL)
-
B2
Junction unit
-
B2
Junction unit
5505A
B5
MAXI FUSE box
-
B38
Additional heater fuse
-
B99
Battery fuses junction unit (CBA)
5530B
C10
Front left earth
-
C15
Facia earth, driver's side
-
C30
Rear left earth
-
C31
Rear right earth
-
D1
Front-dashboard coupling
-
D4
Engine front connection
-
D6
Rear - front coupling
-
D6
Rear-engine compartment coupling
-
D7
Recharging front connection
-
D19
Dashboard / battery coupling
-
D22
Additional heater junction
-
D25
Dashboard-left rear coupling
-
D25
Dashboard-rear coupling left
-
H1
Ignition switch
5520A
I50
Inertial switch
1040A
J36
Additional heater relay
5020M
J36
Webasto pump inhibitor relay.
-
K79
Air temperature sensor (additional heater)(
-
K79
Interior temperaature. sensor for additional heater
-
M75
Additional heater control unit
-
N44
Additional heater pump
-
O25
Additional heater resistance
-
R10
Multiple tester connection
-
file://F:\alfa\eLearn\Web\tempschprint.html
2010/12/01
395400254.002.png
Zgłoś jeśli naruszono regulamin