S7-300_FM_355-2C-2S_e.pdf

(2671 KB) Pobierz
untitled
Preface
SIMATIC Temperature regulator FM 355-2
1
______________
2
______________
SIMATIC
Installing and removing the
FM 355-2
3
______________
Temperature regulator FM 355-2
4
______________
Installing the configuration
package
5
How does the FM 355-2
control?
6
Operating Instructions
7
Integrating the FM 355-2 into
the user program
8
Commissioning the
FM 355-2
9
Properties of digital and
analog inputs and outputs.
10
Connecting measuring
transmitters and
loads/actuators
11
12
13
A
B
C
D
E
Edition 01/2006
A5E00142771-02
F
Product Overview
Structure of the FM 355-2
Wiring the FM 355-2
Controller optimization
Errors and diagnoses
Examples
Data sheets
Optimization status
Assignment of DBs
List of RET_VALU messages
List of abbreviations
Further Information
 
43518236.008.png 43518236.009.png
Safety Guidelines
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
Danger
indicates that death or severe personal injury will result if proper precautions are not taken.
Warning
indicates that death or severe personal injury may result if proper precautions are not taken.
Caution
with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.
Caution
without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.
Notice
indicates that an unintended result or situation can occur if the corresponding information is not taken into
account.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The device/system may only be set up and used in conjunction with this documentation. Commissioning and
operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes
in this documentation qualified persons are defined as persons who are authorized to commission, ground and
label devices, systems and circuits in accordance with established safety practices and standards.
Prescribed Usage
Note the following:
Warning
This device may only be used for the applications described in the catalog or the technical description and only in
connection with devices or components from other manufacturers which have been approved or recommended by
Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly
as well as careful operation and maintenance.
Trademarks
All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this
publication may be trademarks whose use by third parties for their own purposes could violate the rights of the
owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Automation and Drives
Postfach 48 48
90437 NÜRNBERG
GERMANY
Order No.: A5E00142771-02
Edition 01/2006
Copyright © Siemens AG 2006.
Technical data subject to change
43518236.010.png 43518236.001.png 43518236.002.png 43518236.003.png 43518236.004.png
Preface
Purpose of this manual
This manual describes all steps that are necessary to use the function module FM 355-2. It
supports a quick and effective familiarization in the FM 355-2's functionality.
Contents of the manual
This manual describes both the hardware and software of the FM 355-2. It comprises of a
tutorial section and a reference section (see annexes).
The manual covers the following topics:
Controlling with the FM 355-2.
Controller optimization
Installing and removing the FM 355-2
Wiring the FM 355-2
Installing the software package
Programming the FM 355-2
Appendices
Basic knowledge required
To understand the manual, you require general experience in the field of automation
engineering.
You will also need to know how to use computers or PC-like equipment (such as
programming devices) under Windows operating systems.
Scope of this manual
This manual contains a description of the function module FM 355-2, as is valid at the time of
publishing. We reserve the right to describe changes to the functionality of the FM 355-2 in
form of a product information.
Temperature regulator FM 355-2
Operating Instructions, Edition 01/2006, A5E00142771-02
iii
Preface
Position in the Information Landscape
This manual is a component of the S7-300, M7-300 and ET 200M documentation.
System
Documentation
S7-300
1. Automation system S7-300 set-up, CPU data
2. Automation systems S7-300, M7-300, module data
3. S7-300 Operation List
M7-300
1. Automation system M7-300 set-up, CPU data
2. Automation systems S7-300, M7-300, module data
ET 200M
1. ET 200M distributed I/O station
2. Automation systems S7-300, M7-300, module data
Further support
If you have any questions concerning the use of products which are not answered in this
manual, please contact your local Siemens partner at your Siemens office.
http://www.ad.siemens.com/automation/partner
Training center
To familiarize you with S7/M7 automation systems, we offer a variety of courses. Please
contact your regional training center or the central training center in D 90327 Nürnberg:
Telephone: +49 (911) 895-3200
http://www.sitrain.com
Service & Support on the Internet
The Siemens Service & Support team provides you with comprehensive additional
information on SIMATIC products in its online Internet services.
http://www.siemens.com/automation/service&support
There you can find:
our Newsletter that keeps you up to date with the latest information on your products.
The documents you require, using our Service & Support search engine.
A forum, where users and experts from all over the world exchange their experiences.
your local contact for Automation & Drives in our contact database.
Information about onsite services, repairs, spare parts. You will find much more under
"Services".
Temperature regulator FM 355-2
iv
Operating Instructions, Edition 01/2006, A5E00142771-02
43518236.005.png 43518236.006.png
Table of contents
Preface...................................................................................................................................................... iii
1 Product Overview ................................................................................................................................... 1-1
1.1 Introduction ................................................................................................................................ 1-1
1.2 Functionality of the FM 355-2 .................................................................................................... 1-2
1.3 Areas of application for the FM 355-2........................................................................................ 1-4
1.4 The FM 355-2 hardware ............................................................................................................ 1-5
1.5 The FM 355-2 software.............................................................................................................. 1-8
2 Structure of the FM 355-2....................................................................................................................... 2-1
2.1 Basic structure of the FM 355-2................................................................................................. 2-1
2.2 Inputs of the FM 355-2............................................................................................................... 2-4
2.3 Description of the inputs ............................................................................................................ 2-4
2.3.1 Analog inputs ............................................................................................................................. 2-4
2.3.2 Digital inputs............................................................................................................................... 2-7
2.4 Outputs of the FM 355-2............................................................................................................ 2-7
2.5 Operative mechanism of data storage on the FM 355-2 ........................................................... 2-9
2.6 Characteristics of the FM 355-2............................................................................................... 2-13
3 Installing and removing the FM 355-2..................................................................................................... 3-1
3.1 Preparing for Installation............................................................................................................ 3-1
3.2 FM 355-2 installation and removal............................................................................................. 3-3
4 Wiring the FM 355-2............................................................................................................................... 4-1
4.1 Terminal assignment on the front connector ............................................................................. 4-1
4.1.1 FM 355-2 C front connector....................................................................................................... 4-1
4.1.2 FM 355-2 S front connector....................................................................................................... 4-3
4.1.3 Special notes regarding wiring................................................................................................... 4-6
4.2 Wiring Front Connectors............................................................................................................ 4-8
4.3 Module status after initial activation......................................................................................... 4-10
5 Installing the configuration package........................................................................................................ 5-1
Temperature regulator FM 355-2
Operating Instructions, Edition 01/2006, A5E00142771-02
v
43518236.007.png
Zgłoś jeśli naruszono regulamin