Epson DLQ-3000 (upgrade model) Service Manual(1).pdf

(216 KB) Pobierz
DLQ-3000 upgrade model
EPSONIMPACTDOT PRINTER
DLQ-3000
(upgrade model)
SERVICE MANUAL
EPSON
4006094
58098520.008.png
PREFACE
This document provides supplementary information to describe the new DLQ-3000 (Minerva+), which is a
follow-on version of the DLQ-3000 (Minerva). Therefore, you must refer to this information in conjunction with
DLQ-3000 (Minerva) Service Manual for details on any subjects common to both printers.
-i-
58098520.009.png
REVISION SHEET
Revision
Issue Date
Revision Page
A
March 15, 1996
-
1st issue
-ii-
58098520.010.png 58098520.011.png 58098520.001.png 58098520.002.png
DLQ-3000(MINERVA+)
ProductDescription
1.1 FEATURES
Minerva+ is a 24-pin serial dot-matrix and flat-bed type impact printer. As this printer follows on DLQ-3000
(MINERVA+), the main future is almost same as DLQ-3000 (MINERVA).
The main features are ;
o Two built-in and one optional I/F
Bi-Directional Parallel Interface (IEEE-1284 nibble mode)
Serial Interface
Type-B Interface (Option)
The exterior view of DLQ-3000 (MINERVA+) is the same as DLQ-3000 (MINERVA).
Rev.A
1-1
58098520.003.png 58098520.004.png
Product Description
DLQ-3000(MINERVA+)
1.2 INTERFACE OVERVIEW
The printer provides an 8-bit Bi-directional parallel interface and serial interface as standard. Moreover, it is
possible to interface to various computers using the optional type-B interface board. This section describes
the specifications of the standard interfaces.
1.2.1 Parallel Interface Specifications
1.2.1.1 Forward Channel
Transmission mode:
8-bit parallel, IEEE-1284 compatible mode
Synchronization:
By STROBE pulse
Handshaking:
By BUSY and ACKNLG signal
Signal level:
TTL-compatible level, IEEE-1284 level 1 device
Adaptable connector:
57-30360 (Amphenol) or equivalent
Data transmission timing:
See Figure 1-1.
Note:
Transitiontime (rise time andfall time) of every input signalmust be less than 200ns and
everyoutput signalmustbelessthan120 ns.
The BUSY signal is at a HIGH level before either -ERROR signal is at a LOW level or the PE signal is at a
HIGH level until all these signals return to their inactive state. The BUSY signal is at a HIGH level in the
following cases:
- During data reception (see the figure above)
- When the input buffer is full
- When the INIT input signal is active
- During initialization
- When the ERROR signal is active
- In the self-test mode
- In the SelecType
- When the parallel interface is not selected.
The ERROR signal is at a LOW level when the printer is in one of the following conditions:
- Printer hardware error (fatal error)
- A paper-out error
- Release lever operation error
PE signal is at a HIGH level during paper out error.
DATA
DATA (n)
DATA (n+1)
-STORBE
500 ns (min.)
500 ns (min.) 500 ns (min.)
0 (min.)
BUSY
-ACKNLG
0 (min.) 500 ns (max.)
0 (min.)
500 ns ~10 µs
Figure 1-1. Data Transmission Timing
1-2
Rev.A
58098520.005.png 58098520.006.png 58098520.007.png