PS4 PS416-INP-40x h1239g.pdf

(637 KB) Pobierz
PS416-INP-40x, PS416-OUT-4xx
Hardware and Engineering
PS416-INP-40x
PS416-OUT-4xx
Digital I/O Card
01/00 AWB27-1239-GB
1st published 2000, edition 01/00,
See revision protocol page II
© Moeller GmbH, 53105 Bonn
Author: Werner Albrecht
Editor: Thomas Kracht
Translator: Terence Osborn, David Long
All brand and product names are trademarks
or registered trademarks of the owner
concerned.
All rights reserved, including those of the
translation.
No part of this manual may be reproduced in
any form (printed, photocopy, microfilm or
any otherprocess) or processed, duplicated or
distributed by means of electronic systems
without written permission of Moeller GmbH,
Bonn.
Subject to alteration without notice.
457264306.002.png
Warning!
Dangerous electrical voltage!
Before commencing the installation
• Disconnect the power supply of the device.
• Ensure that devices cannot be accidentally
restarted.
• Verify isolation from the supply.
• Earth and short circuit.
• Cover or enclose neighbouring units that
are live.
• Follow the engineering instructions (AWA)
of the device concerned.
• Only suitably qualified personnel in accordance
with EN 50 110-1/-2 (VDE 0 105 Part 100) may
work on this device/system.
• Before installation and before touching the
device ensure that you are free of electrostatic
charge.
• The functional earth (FE) must be connected to
the protective earth (PE) or to the potential
equalisation. The system installer is responsible
for implementing this connection.
• Connecting cables and signal lines should be
installed so that inductive or capacitive interfe-
rence do not impair the automation functions.
• Install automation devices and related opera-
ting elements in such a way that they are well
protected against unintentional operation.
• Suitable safety hardware and software
measures should be implemented for the
I/O interface so that a line or wire breakage
on the signal side does not result in undefined
states in the automation devices.
• Ensure a reliable electrical isolation of the low
voltage for the 24 volt supply. Only use power
supply units complying with IEC 60 364-4-41
(VDE 0 100 Part 410) or HD 384.4.41 S2.
• Deviations of the mains voltage from the rated
value must not exceed the tolerance limits given
in the specifications, otherwise this may cause
malfunction and dangerous operation.
• Emergency stop devices complying with
IEC/EN 60 204-1 must be effective in all
operating modes of the automation devices.
Unlatching the emergency-stop devices must
not cause restart.
• Devices that are designed for mounting in
housings or control cabinets must only be
operated and controlled after they have been
installed with the housing closed. Desktop or
portable units must only be operated and
controlled in enclosed housings.
• Measures should be taken to ensure the proper
restart of programs interrupted after a voltage
dip or failure. This should not cause dangerous
operating states even for a short time. If
necessary, emergency-stop devices should be
implemented.
• Wherever faults in the automation system may
cause damage to persons or property, external
measures must be implemented to ensure a safe
operating state in the event of a fault or
malfunction (for example, by means of separate
limit switches, mechanical interlocks etc.).
I
457264306.003.png 457264306.004.png
List of revisions for AWB27-1239-GB
Edition
Page
Description
new
Modification
01/00
1-3
Tables
X
1-10
Section “PS416-OUT-400/-410”
X
2-3, 2-9
Figure
X
2-10, 2-18
Notes about this manual
X
3-3, 3-4, 3-9
Figure
3-26
Notes about this manual
X
II
457264306.005.png
Overview
About this Manual
V
General
1-1
PS416-INP-400/-401
2-1
PS416-OUT-400/-410
3-1
Appendix
4-1
Index
5-1
III