PNOZ_X5_GB.pdf
(
171 KB
)
Pobierz
Emergency Stop Relays, Safety Gate Monitors
Category 3, EN 954-1
PNOZ X5
Technical Details
PNOZ X5
Electrical Data
Supply Voltage
AC: 24 V
DC: 12, 24 V
1
Tolerance
24 VAC/DC: 85 ... 110 %
12 VDC: 80 ... 120 %
Residual Ripple DC
24 V: 160 %, 12 V: 20 %
Power Consumption
Approx. 2 W/3 VA
Voltage and Current at the Input and
24 VDC/25 mA, 12 VDC/60 mA
Reset Circuits and Feedback Control Loop
Switching Capability in accordance with
EN 60947-4-1, 10/91
AC1:
240 V/6 A/1500 VA
DC1:
24 V/4 A/100 W
EN 60947-5-1, 10/91 (DC13: 6 cycles/min.)
AC15: 230 V/5 A; DC13: 24 V/4A
Output Contacts
2 safety contacts (N/O)
Emergency stop relay and safety
gate monitor in accordance with
VDE 0113-1, 11/98, EN 60204-1,
12/97 and IEC 204-1, 11/98.
Contact Fuse Protection
6 A quick or 4 A slow
(EN 60947-5-1, 10/91)
Times
Delay-on Energisation
Automatic reset :
24 VAC/DC: max. 150 ms
12 VDC: max. 250 ms
Manual reset :
24 VAC/DC: max. 100 ms
12 VDC: max. 150 ms
Features
●
Single-channel or dual-channel
operation without detection of
shorts across the input contacts
Delay-on De-energisation K1, K2
24 VAC/DC: max. 30 ms
12 VDC: max. 30 ms
●
Designed for operation using
semiconductor outputs
Recovery Time
Approx. 1 s
Simultaneity channel 1/2
●
12 VDC version available for
automotive applications
Approx. 10 ms
Max. Supply Interruption before De-energisation
Mechanical Data
Maximum Cross Section of
2 x 1.5 mm
2
or 1 x 2.5 mm
2
External Conductors
Single-core or multi-core
with crimp connectors
Approvals
Dimensions (H x W x D)
87 x 22.5 x 122 mm
Weight
225 g
PNOZ X5
Description
Operating Modes
●
●
22.5 mm, S-95 housing, DIN-Rail
mounting
●
Single-channel operation
●
●
Dual-channel operation
●
Relay outputs, positive-guided:
2 safety contacts (N/O)
●
Automatic reset
●
Manual reset
●
●
Connections for
–
E-STOP button
–
safety gate limit switch
–
reset button
●
LEDs for channel 1, channel 2
and power
●
Increase in the number of
safety contacts available by
connecting expander modules.
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland
NSG-D-2-035-07/01
Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
1-1
Emergency Stop Relays, Safety Gate Monitors
Category 3, EN 954-1
PNOZ X5
Internal Wiring Diagram
● Increase in safety contacts
The number of output contacts can
be increased by using expander
modules or relays/contactors with
positive-guided contacts.
Input circuits
Reset circuit
Safety
contacts
UB
1
A1 (L+)
A2 (L-)
S11
S33
S34
S22
S12
S12
13
23
1L1
K1
Start
Unit
K4
K5
S33
S34
13
K2
Start
Unit
14
24
14
External Wiring
K4
K5
1L2
● Example 1
Dual-channel E-STOP wiring with
manual reset.
● Example 4
Dual-channel safety gate control with
manual reset.
S12
S33
S11
S33
S1
S1
S1
S3
S3
S11
S2
S34
S22
S34
S12
S22
● Example 2
Dual-channel E-STOP wiring with
automatic reset.
–
Key
S11
S33
S1/2:
E-STOP or safety gate switch
S3:
Reset button
S1
Switch operated
Gate open
Gate closed
S12
S22
S34
● Example 3
Single-channel E-STOP wiring with
manual reset.
S11
S12
S33
S1
S3
S34
S12
S22
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland
NSG-D-2-035-07/01
Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
Emergency Stop Relays, Safety Gate Monitors
Category 3, EN 954-1
PNOZ X5
General Technical Data
Unless stated otherwise in the technical details for the specific unit
1
Electrical Data
Frequency Range AC
50 ... 60 Hz
Residual Ripple DC
160 %
Contact Material
AgSnO
2
Continuous Duty
100 %
Environmental Data
EMC
EN 50081-1, 01/92, EN 50082-2, 03/95
Vibration in accordance with
Frequency: 10 ... 55 Hz,
EN 60068-2-6, 04/95
Amplitude: 0.35 mm
Climatic Suitability
DIN IEC 60068-2-3, 12/86
Airgap Creepage
DIN VDE 0110 part 1, 04/97
Ambient Temperature
-10 ... +55 °C
Storage Temperature
-40 ... +85 °C
Mechanical Data
Torque Setting on Connection Terminals
0.6 Nm (screws)
Mounting Position
Any
Housing Material
Thermoplast Noryl SE 100
Protection
Mounting: IP 54
Housing: IP 40
Terminal Range: IP 20
The units were tested in accordance with the relevant standards current at
the time of development.
Order References
Type
U
B
Order No.
PNOZ X5
24 V DC
774 325
Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland
NSG-D-2-035-07/01
Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
1-3