ET B1 Add On 2008 Modular Installation Devices - Installation Depth 5 mm
© Siemens AG 2007
%!"
#7'*8
9
%
%-:!;
9#
768802484.034.png 768802484.035.png 768802484.036.png 768802484.037.png
© Siemens AG 2007
Catalogs for the division:
Electrical Installation Technology
© Siemens AG 2007
ALPHA Distribution Boards,Terminal Blocks
and Meter Cabinets
ALPHA Distribution Boards and
Terminal Blocks
Order No.:
pdf only: (E86060-K8210-A101-A8-7600)
ET A1
ALPHA 400-ZS Meter Cabinets
Order No.:
Regional catalogs available on request
(available in German only)
ET A2
BETA Low-Voltage Circuit Protection
Order No.:
pdf only: (E86060-K8220-A101-A9-7600)
ET B1
GAMMA Building Management Systems
Order No.:
pdf only: (E86060-K8230-A101-A8-7600)
ET G1
DELTA Switches and Socket Outlets
Order No.:
pdf only: (E86060-K8240-A101-A8-7600)
ET D1
The A&D Offline Mall
Order No.:
E86060-D4001-A110-C6-7600 (CD-ROM)
E86060-D4001-A510-C6-7600 (DVD)
CA 01
Internet
Visit our Automation and Drives Web site on the
Internet. You will find us at the following addresses
• Automation and Drives:
http://www.siemens.com/automation
• Electrical Installation Technology:
http://www.siemens.com/e-installation
• for the A&D Mall:
http://www.siemens.com/automation/mall
Registered trademarks
All product designations may be registered
trademarks or product names of Siemens AG or
other supplying companies. Third parties using
these trademarks or product names for their own
purposes may infringe upon the rights of the
trademark owners.
Figures given in inches are only valid for export
purposes according to the „Law on units in
measuring systems“.
768802484.001.png 768802484.002.png 768802484.003.png 768802484.004.png 768802484.005.png 768802484.006.png 768802484.007.png
 
© Siemens AG 2007
Modular Installation Devices,
Mounting Depth 55 mm >N<
Miniature Circuit Breakers
2
Additional components for 5SX2
5
Accessories for 5SX2
Residual Current Protective Devices
6
5SM1 residual current operated
circuit breakers (RCCBs), type A, 16 ... 80 A
8
Additional components for 5SM1
8
Accessories for 5SM1
Switches
9
5TE7 1 and 5TE7 2 switches
9
5TE7 5 switches
Switching Devices
10
5TT5 remote control switches
10
5TT3 0 switching relays
1 1
5TT3 8 Insta contactors
Timers
12
5TT1 3 time switches for building lighting
12
7LF4 4 digital time switches
1 3
7LF5 3 mechanical time switches
Transformers
1 4
4AC2 9 transformers
Monitoring Devices
15
7LQ2 1 dusk switches
1 5
5TT3 45 alarm sensors, 55/70 mm
Busbars
16
5ST2 13 ... 5ST2 16 busbars with
fork-type connections
17
5ST2 18, 5ST2 19 busbars with
fork-type connections
18
5ST2 4 busbars with
fork-type connections
19
Product Changeover
Note: Only the chapters indicated in black on this
page contain selection and ordering data.
Abbreviations:
MW Modular width 18 mm
PS Packaging size
P. unit Packaging unit
Siemens ET B1 AO · 2008, 55-mm devices
1
© Siemens AG 2007
4
5SX2, 6 kA
768802484.008.png 768802484.009.png 768802484.010.png 768802484.011.png 768802484.012.png
© Siemens AG 2007
Modular Installation Devices, Mounting Depth 55 mm >N<
Miniature Circuit Breakers
© Siemens AG 2007
1
2
5SX2, 6 kA
Application
U n : 230/400 V, 50 ... 60 Hz, can be used in systems up
to 250/440 V AC, 60 V DC per pole
3
• Standards: IEC/EN 60898, DIN VDE 0641-11
• Additional components can be retrofitted individually.
Selection and ordering data
I n
MW
Characteristic B
PS*/
P. u n i t
Characteristic C
Weight
per
P. unit
approx
PS*/
P. unit
4
Order No.
Order No.
A
Unit(s)
kg
Unit(s)
1-pole
5
0.3
1
--
5SX2 114-7
0.140
1
0.5
--
5SX2 105-7
0.140
1/12
1
--
5SX2 101-7
0.141
1/12
1.6
--
5SX2 115-7
0.140
1
2
--
5SX2 102-7
0.141
1/12
3
--
5SX2 103-7
0.140
1/12
6
4
--
5SX2 104-7
0.141
1/12
6
5SX2 106-6
1/12
5SX2 106-7
0.138
1/12
8
--
5SX2 108-7
0.140
1/12
10
5SX2 110-6
1/12
5SX2 110-7
0.141
1/12
13
5SX2 113-6
1/12
5SX2 113-7
0.140
1/12
7
16
5SX2 116-6
1/12
5SX2 116-7
0.134
1/12
20
5SX2 120-6
1/12
5SX2 120-7
0.138
1/12
32 1)
5SX2 125-6
1/12
5SX2 125-7
0.143
1/12
5SX2 132-6
1/12
5SX2 132-7
0.140
1/12
1-pole + N
8
6
2
5SX2 506-6
1
5SX2 506-7
0.210
1/6
10
5SX2 510-6
1
5SX2 510-7
0.210
1/6
13
5SX2 513-6
1/6
5SX2 513-7
0.210
1/6
16
5SX2 516-6
1/6
5SX2 516-7
0.210
1/6
20
5SX2 520-6
1
5SX2 520-7
0.210
1
25
5SX2 525-6
1
5SX2 525-7
0.210
1
9
32
5SX2 532-6
1
5SX2 532-7
0.210
1
2-pole
0.5
2
--
5SX2 205-7
0.280
1
1
--
5SX2 201-7
0.280
1/6
1.6
--
5SX2 215-7
0.280
1
10
2
--
5SX2 202-7
0.280
1/6
3
--
5SX2 203-7
0.280
1/6
4
--
5SX2 204-7
0.280
1/6
6
5SX2 206-6
1/6
5SX2 206-7
0.276
1/6
8
--
5SX2 208-7
0.280
1
11
10
5SX2 210-6
1/6
5SX2 210-7
0.280
1/6
13
5SX2 213-6
1
5SX2 213-7
0.280
1
16
5SX2 216-6
1/6
5SX2 216-7
0.280
1/6
20
5SX2 220-6
1
5SX2 220-7
0.280
1/6
25
5SX2 225-6
1
5SX2 225-7
0.280
1/6
12
32
5SX2 232-6
1
5SX2 232-7
0.280
1/6
The versions 5SX2 B 6 ... 32 and C 0.5 ... 32 1-pole, 2-pole and 3-pole
are certified to UL 1077 and CSA 22.2 No. 235-M 89 and can be
used as supplementary protectors up to 277 V AC (1-pole) and
480 V AC (2-pole, 3-pole).
Additional components see page 4.
Accessories see page 5.
1)
13
Also suitable for 21-kW active power with three-phase currents of 400 V
(e.g. continuous-flow heaters with short-time operation duty) or 7-kW active
power at 230 V AC (e.g. storage in not-continuous operation duty).
For continuous load applications, we recommend using miniature circuit
breakers, characteristic B or C and I n =40A.
14
15
16
17
2
Siemens ET B1 AO · 2008, 55-mm devices
* You can order this quantity or a multiple thereof.
25
768802484.013.png 768802484.014.png 768802484.015.png 768802484.016.png 768802484.017.png 768802484.018.png 768802484.019.png 768802484.020.png 768802484.021.png
© Siemens AG 2007
Modular Installation Devices, Mounting Depth 55 mm >N<
Miniature Circuit Breakers
© Siemens AG 2007
1
5SX2, 6 kA
2
Selection and ordering data
I n
MW Characteristic B
PS*/
P. u n i t
Characteristic C
Weight
per
P. unit
approx
PS*/
P. unit
3
Order No.
Order No.
A
Unit(s)
kg
Unit(s)
3-pole
0.5
3
--
5SX2 305-7
0.440
1
4
1
--
5SX2 301-7
0.440
1
1.6
--
5SX2 315-7
0.440
1
2
--
5SX2 302-7
0.440
1/4
3
--
5SX2 303-7
0.440
1
4
--
5SX2 304-7
0.440
1/4
5
6
5SX2 306-6
1
5SX2 306-7
0.440
1/4
8
--
5SX2 308-7
0.440
1
10
5SX2 310-6
1/4
5SX2 310-7
0.440
1/4
13
5SX2 313-6
1
5SX2 313-7
0.440
1
16
5SX2 316-6
1/4
5SX2 316-7
0.440
1/4
6
20
5SX2 320-6
1
5SX2 320-7
0.440
1/4
32 1)
5SX2 325-6
1
5SX2 325-7
0.434
1/4
5SX2 332-6
1/4
5SX2 332-7
0.440
1/4
3-pole + N
6
4
--
5SX2 606-7
0.450
1
7
10
5SX2 610-6
1
5SX2 610-7
0.450
1
13
5SX2 613-6
1
5SX2 613-7
0.450
1/3
16
5SX2 616-6
1
5SX2 616-7
0.450
1/3
20
5SX2 620-6
1
5SX2 620-7
0.450
1
25
5SX2 625-6
1
5SX2 625-7
0.450
1
32
5SX2 632-6
1
5SX2 632-7
0.450
1/3
8
4-pole
6 2)
4
--
5SX2 406-7
0.590
1
10 2)
--
5SX2 410-7
0.590
1
13 2)
--
5SX2 413-7
0.590
1
16 2)
--
5SX2 416-7
0.590
1
9
5SX2 420-6
1
5SX2 420-7
0.590
1
25 2)
5SX2 425-6
1
5SX2 425-7
0.590
1
32 2)
5SX2 432-6
1
5SX2 432-7
0.590
1
The versions 5SX2 B 6 ... 32 and C 0.5 ... 32 1-pole, 2-pole and 3-pole
are certified to UL 1077 and CSA 22.2 No. 235-M 89 and can be
used as supplementary protectors up to 277 V AC (1-pole) and
480 V AC (2-pole, 3-pole).
For additional components, see page 4.
Accessories, see page 5.
1)
10
Also suitable for 21-kW active power with three-phase currents of 400 V
(e.g. continuous-flow heaters with short-time operation duty) or 7-kW
active power at 230 V AC (e.g. storage in not-continuous operation duty).
For continuous load applications, we recommend using miniature circuit
breakers, characteristic B or C and I n =40A.
11
Without V mark.
12
2)
13
14
15
16
* You can order this quantity or a multiple thereof.
Siemens ET B1 AO · 2008, 55-mm devices
3
17
25
20 2)
768802484.022.png 768802484.023.png 768802484.024.png 768802484.025.png 768802484.026.png 768802484.027.png 768802484.028.png 768802484.029.png 768802484.030.png 768802484.031.png 768802484.032.png 768802484.033.png
Zgłoś jeśli naruszono regulamin