Mira System plus
Mira Green System plus
BACD (storage tank) connection kit
C
737451736.022.png
Kit to connect the boiler with an external tank
With this kit, the Mira can be connected with an external tank (BACD) to give top comfort DHW.
Kit packaging :
Kit details
The kit consist of several elements :
- DHW expansion vessel, pipes, wires and fitting manual
C
The boiler fitted with an external DHW cylinder :
When the cylinder thermostat is on, the 3 way valve
moves in the cylinder heating position.
A
D
B
Cylinder
return circuit
The pump and burner are working until the
temperature set on the cylinder thermostat is
reached.
To CH
+ cylinder
BACD
A - Central heating and cylinder flow
B - Cylinder return circuit
C - Gas inlet
D - Central heating return
E - Central heating flow
E
-2-
737451736.023.png 737451736.024.png 737451736.025.png 737451736.001.png 737451736.002.png 737451736.003.png 737451736.004.png 737451736.005.png 737451736.006.png 737451736.007.png
}
Boiler Mira system plus
A
C
D
} }
E
B
Domestic hot water outlet
Kit 3678035
Domestic cold
water intlet
BACD Cylinder
To order separately
A
C
E
D
B
DCW
DHW
-3-